YM series high power CO2 laser generator has absolute advantages compared with the like products in the present market, with photoelectric conversion ratio up to 30%, laser power stability about ±1%,much lower electricity consumption & air consumption and high quality laser beam.
|
Features:
◆Stable steel structure design and constant temperature control
◆Parallel plane laser resonance cavity
◆World famous components
◆Laser path reflection protection function
◆Vertical pattern control function to ensure the stable laser mode
◆Fast axis cooling and high efficient heat exchanger
◆Working gases flux speed is adjustable and laser output power optimized
◆Working gases is mixed according to the ratio to ensure the stable laser outputting
◆Multiple vacuum seal technology to ensure the gases purity and lower the operation cost
◆Electricity-Optic exchange rate is up to 30%
◆PLC intelligent control system to ensure the stable working of the laser generator
◆Colorful LCD display, 17" touch screen, standard keyboard, mouse, Chinese/English interface etc. are convenient for your operation.
◆Module designs, and partial module malfunction has no effect on the working.
◆Intelligent protection for the over-current, over-pressure. All kinds of safty measures are available
Techinial Index:
Item/Performance Index
|
Parameters
|
Wave-Length
|
10.6um
|
Rating Outputting Power
|
2400W
|
Maximum Outputting Power
|
2600W
|
Power Stability
|
<=1%
|
M2
|
<=1.2
|
Adjustable Range for the Continous Outputting Power
|
90W-max
|
Facula Size
|
20±0.5mm
|
Laser Beam Radiation Angle
|
<=1.5 mrad
|
Mode
|
TEM01
|
Laser Generating Module Quantity
|
IV
|
Generating Method
|
DC generating
|
Working
|
CW -1000Hz
|
Dimension
|
2650(L) x910 (W) x1690(H)mm
|
Weight
|
1100kg
|
Laser Power
|
AC 380V 5%:50/60Hz:3phase :neutral line: earthing:
17kVA; 3x60A fuse
|
Cooling Water (Double Temperature)
|
Low temperature:50L/min;0.45-0.6MPa(pressure):18°C
High temperature:22°C
Water quality:solid impurity:<=50um:Max water rigidity:15
|
Circumstances Temperature
|
4°C-26°C
|
Circumstances Humidity
|
<=85%
|
Compressed Air
|
0.4-0.8Mpa oil-free, water-free, dust-free
|
Gas Consumption
|
<= 45 NL / h purity:99.999%
|
Controlling Mode
|
Inner-outer control ( 0-10V analog signals)
|
Consumables:
Working Gases:
N2 ( 27.5% ) , CO2 ( 2.5% ),He (70% )
Mixed Gases Purity:>=99.999%
Consumption:<=45NL/h
Assisting Gas:N2
Purity: 99.999%
Consumption: 25NL/time
|